Development and validation of a novel bioassay to determine glucocorticoid sensitivity

Abstract

Background

Glucocorticoids (GCs) remain the first line treatment for almost all non-infectious inflammatory diseases, ranging from acute asthma to rheumatoid arthritis. However, across all conditions, patients have a variable response to GCs with approximately 30% being non-responders. This group of GC resistant patients is typically exposed to high-dose GCs and their side-effects before more appropriate immunotherapy is instituted. Hence, there is a pressing clinical need for a predictive biomarker of GC responsiveness. The availability of such a tool would also enable patient stratification for the conduct of smart clinical trials in GC resistance. Lymphocyte GC sensitivity has been shown to be closely associated with clinical GC sensitivity in a number of inflammatory diseases. However, the method for determining in vitro GC response is not standardized and requires the use of specialist equipment, including a radioisotope to quantify cellular proliferation, making it challenging to translate into clinical practice.

Results

Here we describe the optimization and validation of a novel non-radioactive in vitro bioassay based on measuring cellular proliferation by incorporation of bromodeoxyuridine (BrdU), termed the BrdU incorporation in lymphocyte steroid sensitivity assay (BLISS). In comparison to the current gold standard lymphocyte GC sensitivity assay in 101 healthy control samples, BLISS has an area under receiver operating characteristic of 0.82 and a sensitivity of 83% for correctly identifying GC resistant subjects.

Conclusions

The performance of the novel BLISS bioassay makes it a strong candidate biomarker for clinical application. It now requires validation in a prospective patient cohort.

Background

For more than half a century glucocorticoids (GCs) have formed the mainstay of the initial treatment of almost all non-infectious inflammatory diseases including asthma, inflammatory bowel disease, rheumatoid arthritis, non-infectious uveitis and acute severe alcoholic hepatitis. However, response to GCs in patient populations is variable and in each disease group a cohort of GC non-responders (approximately 30% of all patients) has been clearly described [1–4]. GC resistant patients are both at risk of the consequences of their uncontrolled disease and, because they require higher and longer courses of therapy, they also incur a greater burden of treatment side-effects. This could be avoided if alternative immunotherapeutics were to be instituted early in their disease course, but at present there is no way of identifying GC resistant individuals prior to GC treatment. Hence, there is an overt clinical need to develop a biomarker of GC resistance prior to induction of therapy as a tool for personalized healthcare.

GCs have wide ranging effects on many cells and tissues. They bind to cytoplasmic GC receptors, which translocate to the nucleus and bind to DNA at GC responsive elements resulting in transcriptional regulation by either transactivation or transrepression of target genes, leading to reduction in inflammation. The main mechanism of GC anti-inflammatory action is through interference with pro-inflammatory transcription factors such as nuclear factor kappa B and activator protein 1 [5]. Although efficacious in many diseases, prolonged exposure to GCs results in numerous undesirable side-effects including osteoporosis, diabetes, infection and increased cardiovascular risk [6, 7]. Therefore GCs should be used selectively in responsive patients where a therapeutic benefit can be achieved. Measurement of individual GC sensitivity could therefore be crucial to permit appropriate stratified treatment.

In patients with bronchial asthma it was demonstrated that GC sensitivity correlated with in vitro lymphocyte GC sensitivity rather than with a measure of disease severity, decline in lung function [8, 9]. In these studies, GC sensitivity was quantified in vitro by measuring the inhibitory effect of dexamethasone (a synthetic GC) on phytohaemagluttinin (PHA)-induced lymphocyte proliferation in peripheral blood mononuclear cells (PBMCs). This assay, known as the Dexamethasone Inhibition of Lymphocyte Proliferation Assay (DILPA), demonstrates a wide range in GC sensitivity in healthy controls, which is stable over time and not related to intrinsic cortisol production [10]. Approximately 30% of the reported population, and also in other healthy control populations, are classified as GC resistant by DILPA [10, 11], which corresponds to the overall proportion of GC resistant patients. This suggests that the individual’s GC sensitivity is inherent in the presence or absence of disease. When applied to inflammatory diseases DILPA predicts clinical GC response better than traditional measures of disease severity in patients with ulcerative colitis [12, 13], alcoholic hepatitis [3, 14] and rheumatoid arthritis [15].

Traditionally, in order to quantify lymphocyte GC sensitivity, cell proliferation is determined by labelling dividing cells with tritiated thymidine (3H, a radioisotope of hydrogen) and measuring the beta radiation emission using a beta counter. This technique necessitates expensive equipment that is not widely available in many healthcare or commercial laboratories. Alongside this, there are stringent health and safety standards that can impede the use of radiation for many organizations. The clinical translation of this assay has therefore been limited and currently only a few institutions are performing the DILPA in a research setting.

There is consequently a requirement for an alternative GC sensitivity assay which can be easily performed in any laboratory setting. Therefore, the aim of this study was to develop and validate a novel bioassay to measure in vitro GC sensitivity. Bromodeoxyuridine (BrdU) is a synthetic pyrimidine analogue of thymidine, which is incorporated into the DNA of cells undergoing division in the S phase of the cell cycle and can be detected using labelled antibodies to BrdU by chemiluminescence, flow cytometry or colorimetric assays. Therefore, detection of newly synthesized DNA using BrdU can be used as an indirect measure of cell proliferation [16–18]. Using a commercially available colorimetric assay, which does not require bespoke equipment or expertise, we have developed a novel measure of GC sensitivity termed the BrdU Lymphocyte Incorporation Steroid Sensitivity (BLISS) assay. In this report we describe the full assay protocol and validation of the BLISS assay to measure clinical GC sensitivity in comparison to the standard DILPA.

Methods

This study was conducted under ethical approval from the NHS Health Research Authority (reference: 04/Q2002/84). After obtaining written informed consent 20 mL peripheral blood was taken from healthy subjects by standard venepuncture into EDTA collection tubes. PBMCs were isolated by density gradient centrifugation over Ficoll-Paque Plus (VWR International, Lutterworth, Leicestershire, UK) using Leucosep tubes (Greiner Bio-One International, Stonehouse, Gloucestershire, UK) and cell viability assessed by Trypan blue exclusion. Cells were counted manually by light microscopy using a hemocytometer.

DILPA

The DILPA was performed as previously described [3, 12]. In brief, 2 × 106 PBMCs / ml were suspended in RPMI media (Thermo Fisher Scientific, Loughborough, Leicestershire, UK) supplemented with 10% heat inactivated fetal calf serum (Thermo Fisher Scientific), 2 mM L-glutamine (Thermo Fisher Scientific) and 100 U/mL penicillin and streptomycin (Thermo Fisher Scientific). Cells were cultured in a 96-well plate in triplicate with 20 μg/mL PHA (Sigma-Aldrich, Poole, Dorset, UK) in the presence or absence of 1 × 10−6 M Dexamethasone (Sigma-Aldrich, Poole, Dorset) for 42 h at 37°C with 5% CO2. A saturating dose of 185 kBq/ml 3H was then added and cultured for a further 6 h. Control wells with unstimulated cells were also included. The plate was harvested onto glass fibre filter paper (Wallac Oy, Turku, Finland) using a cell harvester (Skatron, Cox Scientific, Rothwell, Northamptonshire, UK) and beta emission measured using a Micro β emission scintillation counter (Wallac) in counts per minute (cpm). Samples with cpm < 10,000 were considered a technical failure and excluded from analysis (n = 6 in the optimization phase of experiments).

BLISS assay

PBMCs were isolated and cultured for 42 h in triplicate as described for the DILPA. Control wells of media alone, BrdU reagent alone and anti-BrdU-peroxidase antibody alone were also included in triplicate. BrdU reagent was added for the final 6 h of culture at 10 μM. BrdU was then detected using a commercial kit according to the manufacturer’s instructions (Roche Diagnostics, Burgess Hill, UK). The protocol was optimized to determine the most appropriate cell density, processing time and time of exposure to the developing substrate. The final standardized protocol is described fully in the results section.

Statistical analysis

For the standard DILPA and BLISS assay the maximum percentage inhibition of proliferation (Imax) was calculated:

$$ \mathrm{Imax} = \left(1\ \hbox{--}\ \left[\mathrm{proliferation}\ \mathrm{in}\ \mathrm{presence}\ \mathrm{of}\ \mathrm{G}\mathrm{C}\right]\ /\ \left[\mathrm{proliferation}\ \mathrm{in}\ \mathrm{absence}\ \mathrm{of}\ \mathrm{G}\mathrm{C}\right]\right) \times 100 $$

Although Imax values for both DILPA and BLISS give a percentage suppression of proliferation by GCs, the underlying assays use different methods with different units and scales. Therefore, in order to place both assays on a similar scale to compare the results more meaningfully, the BLISS dataset was first calibrated using an inverse regression model.

A Bland and Altman test of agreement was then performed between DILPA and the adjusted BLISS and 95% limits of agreement were determined [19].

To assess the accuracy of the adjusted BLISS Imax in predicting DILPA Imax an area under receiver operating characteristic (AUROC) was calculated and compared to the diagonal reference line.

The previously determined threshold to define GC sensitivity of Imax = 60% [10] was applied to the DILPA dataset. The 60% threshold was adjusted according to the inverse regression model and applied to the BLISS dataset. Accuracy of the BLISS assay was compared to the DILPA applying the adjusted threshold to produce categorical data to give a contingency table.

Results

Subjects

Following optimization, 101 assays were performed on samples from unique healthy individuals using the standardized BLISS assay technique as described below.

There were no DILPA values excluded from the final analysis due to technical failure with low proliferation in PHA stimulated wells < 10,000 cpm. For the BLISS assay there was a single technical failure for sample with low proliferation in the PHA stimulated wells which was not included in the final analysis.

Standardized BLISS assay protocol

PBMCs were cultured at 2 × 106 / ml in triplicate in a 96-well plate exactly as described for the standard DILPA with 20 μg/ml PHA in the presence or absence of 1 × 10−6 M dexamethasone at 37°C with 5% CO2 for 42 h in a total volume of 200 μL. Twenty microlitre per well BrdU labelling solution diluted 1:100 in RPMI supplemented with 10% FCS, L-glutamine and antibiotics (complete media) were added to all experimental wells and to media alone for a negative control and cultured for a further 6 h. Cells were resuspended and the entire well volume transferred directly to a 96-well flat bottomed plate and centrifuged for 10 min at 300 g. Supernatants were aspirated and discarded. The plate was dried for 1 h in a 60°C oven or for 15 min using a standard hair drier. The dry plate was covered and left overnight at 4°C. For more rapid results this step can be omitted by proceeding directly to fixing the cells and denaturing the DNA. Results are similar if processed directly or after keeping at 4°C overnight (Pearson’s r = 0.82 for 29 subjects). 200 μL / well of FixDenat solution was added to fix and denature the DNA and incubated for 30 min at room temperature. FixDenat solution was removed by flicking off and tapping plate. 100 μL / well anti-BrdU-peroxidase conjugate (pre-diluted at 1:100 with antibody diluent solution) was added to all experimental wells and to negative control wells. The plate was incubated for 90 min at room temperature. Antibody solution was removed by flicking off and tapping plate. Plates were washed three times with 200 μL / well of washing solution diluted 1:10 with distilled H2O. A final wash was performed with 200 μL / well Phosphate Buffered Saline (PBS). Wash solution was removed by flicking off and tapping plate. 100 μL / well of substrate was added and incubated for 5 min at room temperature. Absorbance of the samples was measured in an ELISA plate reader at 370 nm (reference wavelength 492 nm). Absorbance (A370nm–A492nm) was calculated for each well. The value for Imax was then also calculated as shown above.

BLISS and DILPA data have different distributions

The Imax values for both assays are approximately normally distributed, confirming that there is a range of GC sensitivity seen in the healthy population (Fig. 1). However, the mean and standard deviations (sd) for each test are significantly different: mean DILPA is 48.2% (sd 26.3%) and mean BLISS is 32.5% (sd 21.2%) (p < 0.001; unpaired t test).

Fig. 1
figure 1

Distribution of Imax for DILPA a and BLISS assay b. Frequencies have been binned in 10% groups in 101 healthy control samples and the normal distribution curve overlaid. The mean and standard deviation for DILPA is 48% and 26 and for BLISS 32% and 21, respectively. Their distributions are significantly different (unpaired t-test p < 0.001)

BLISS assay accurately predicts GC resistance

Inverse regression provides the following model:

$$ \mathrm{BLISS}\ \mathrm{Imax} = 6.8 + \left(0.53 \times \mathrm{DILPA}\ \mathrm{Imax}\right) $$

The BLISS dataset was then adjusted by using the equation (BLISS Imax–6.8) / 0.53 and a Bland and Altman test of agreement was performed (Fig. 2). The bias was found to be −0.2% with 95% limits of agreement from −59.2 to 58.7%.

Fig. 2
figure 2

Bland and Altman test of agreement for DILPA and BLISS. Bland and Altman plot of average versus difference for DILPA and BLISS (adjusted by the inverse regression model of 6.8 + [5.3 × DILPA]). Bias (mean difference between DILPA and BLISS) is −0.2% with 95% limits of agreement from −59.2 to 58.7% (dashed lines)

Using the adjusted BLISS dataset to predict DILPA, AUROC was 0.82 (95% confidence interval [CI]: 0.73–0.92; p < 0.001; Fig. 3).

Fig. 3
figure 3

BLISS has a high accuracy in predicting DILPA. Receiver operating characteristic for BLISS (adjusted by inverse regression model) in predicting DILPA with diagonal reference line (dashed). AUROC = 0.82 (95% CI 0.73–0.92; p < 0.001 compared to reference line)

Applying the inverse regression model to the predefined threshold for GC sensitivity of 60% for DILPA [12] gives a threshold of 38.7% for BLISS. Classifying subjects as GC sensitive or GC resistant using the predefined threshold for the DILPA and the adjusted threshold for BLISS demonstrates that the BLISS assay has 83% sensitivity (95% CI: 71–90%) and 69% specificity (95% CI: 50–83%) compared to the DILPA (Table 1).

Table 1 Contingency table comparing classification of GC sensitive (GC-S) and resistant (GC-R) subjects by DILPA and BLISS assays

Discussion

Here we report the use of the novel BLISS assay to determine GC sensitivity. It has a suitably high AUROC (0.82) and sensitivity in correctly identifying GC non-responders (83%) in reference to the existing gold standard lymphocyte GC sensitivity assessment method (DILPA). The sensitivity of BLISS in identifying GC non-responders is the most important measure of diagnostic accuracy; it must correctly identify those patients who do not respond to GCs so as to reliably reduce their unnecessary exposure to GCs and guide alternative management. Secondly, it is important to identify those who can benefit from GCs so as not to inappropriately withhold GC treatment. Therefore specificity of BLISS is of secondary importance (69% in comparison to DILPA).

The simplicity of the assay, which uses a commercially available kit and does not require complex equipment or processing techniques, means it can be performed in any laboratory that has cell culture facilities. Unlike the DILPA, the BLISS assay does not have any radiation safety concerns and does not require the purchase and maintenance of expensive laboratory equipment. The BLISS assay is also more reliable than the DILPA. In 10 subjects who had DILPA and BLISS repeated on a second occasion several weeks later, there was poor correlation with their previous DILPA Imax value (r = 0.45). The BLISS assay demonstrated closer correlation (r = 0.59). In addition, there was also <1% technical failure rate. These attributes make this an appealing assay to apply to patients with a range of inflammatory and autoimmune diseases with potential to allow clinicians to stratify patient risk and develop more individualized treatment programs.

We note that the Bland and Altman test of agreement demonstrated wide 95% limits of agreement between the DILPA and BLISS assays. This is likely to reflect the variability of functional assays and particularly the measurement of proliferation by 3H incorporation and beta emission detection. However, the Bland and Altman test of agreement is not an appropriate statistical measure for comparison between the DILPA and BLISS since, although readings are converted to the same units (Imax), the underlying quantities differ (cpm and absorbance) [20]. Therefore, regression together with AUROC analysis and a categorical comparison are more appropriate to determine whether the BLISS assay is similar to the DILPA in identifying GC resistant patients. Additionally, in a cohort of healthy controls in the absence of disease it is impossible to correlate either assay with clinical phenotype and steroid responsiveness. Therefore the BLISS assay now requires validation in a cohort of patients with inflammatory diseases. Such validation is currently underway in a cohort of patients with acute severe alcoholic hepatitis, an inflammatory disease of the liver in which GCs are the only treatment known to improve survival. Preliminary data from 10 patients demonstrate that the BLISS assay significantly correlates with the current gold standard measure of GC responsiveness known as the Lille score with a correlation coefficient of −0.74 (p = 0.02; Additional file 1: Table S1) [21]. The Lille score is calculated from clinical and biochemical parameters after 7 days of GC treatment with higher Lille scores associated with greater GC resistance (hence the negative correlation coefficient). This suggests that the BLISS assay has clinical translatability which will be addressed after the adequately powered study in 200 patients has been completed.

In this normal volunteer cohort we applied an adjusted GC sensitivity threshold to the BLISS assay based on the inverse regression model. However, this may not be appropriate because there is a different distribution of BLISS assay Imax with a lower mean and standard deviation than the DILPA. Accurate determination of the best threshold to define GC sensitivity is best achieved in a new cohort of patients with clear clinical definitions of GC sensitivity and resistance, which are independent of the assay.

In current clinical practice, GC responsiveness is determined by changes in clinical symptoms or disease activity scores specific to the condition, which can take several days to respond. For example, in patients with acute severe alcoholic hepatitis GC response is determined at day 7 of treatment according to the Lille score [21]. Although the BLISS assay represents a significant improvement in the speed of determining clinical GC responsiveness, results still take a little over 48 h to obtain. This may be relevant in certain conditions in which urgent GC treatment cannot be delayed (e.g. acute severe ulcerative colitis or acute life-threatening asthma). However, harm to the patient from a short period of GC treatment is unlikely and the BLISS assay will still have clinical utility to guide subsequent patient management such as escalating therapy in GC resistant patients.

Alternative methods have been reported to measure cell proliferation by BrdU incorporation including chemiluminescence and flow cytometry [17, 22]. The chemiluminescence method is similar to the colorimetric assay but uses a different substrate with 2 components and requires a luminometer with photomultiplier to detect light emission. Our proposed protocol uses a premixed substrate and ELISA plate reader to measure wavelength absorbance, making it marginally easier to apply. Flow cytometry methods for BrdU measurement allow quantification at a single cell level. However, flow cytometry requires the appropriate expertise and equipment and may struggle with high throughput, limiting its generalizability and translation into clinical laboratories. The colorimetric assay we describe here is therefore the most streamlined and easily accessible technique to measure cell proliferation.

Conclusions

In summary, we have reported the validation of a simple novel bioassay with a standardized laboratory protocol which accurately measures GC sensitivity. This has broad translational implications and could be applied to many inflammatory diseases to guide clinical management of individual patients, ensuring that GC responsive patients are correctly treated with GCs while reducing unnecessary exposure to GCs and accelerating the appropriate escalation of treatment of GC resistant patients. Further validation in a clinical context is ongoing.

Abbreviations

AUROC:

Area under receiver operating characteristic

BLISS:

BrdU in lymphocyte incorporation steroid sensitivity assay

BrdU:

Bromodeoxyuridine

DILPA:

Dexamethasone inhibition of lymphocyte proliferation assay

GC:

Glucocorticoid

Imax:

Maximum inhibition of proliferation with dexamethasone

PBMC:

Peripheral blood mononuclear cell

PHA:

Phytohaemagluttinin

References

  1. Carmichael J, Paterson IC, Diaz P, Crompton GK, Kay AB, Grant IW. Corticosteroid resistance in chronic asthma. Br med j (clin res ed). 1981;282(6274):1419–22.

    Article  CAS  Google Scholar 

  2. Corkill MM, Kirkham BW, Chikanza IC, Gibson T, Panayi GS. Intramuscular depot methylprednisolone induction of chrysotherapy in rheumatoid arthritis: a 24-week randomized controlled trial. Br j rheumatol. 1990;29(4):274–9.

    Article  CAS  PubMed  Google Scholar 

  3. di Mambro AJ, Parker R, McCune A, Gordon F, Dayan CM, Collins P. In vitro steroid resistance correlates with outcome in severe alcoholic hepatitis. Hepatology. 2011;53(4):1316–22.

    Article  PubMed  Google Scholar 

  4. Faubion Jr WA, Loftus Jr EV, Harmsen WS, Zinsmeister AR, Sandborn WJ. The natural history of corticosteroid therapy for inflammatory bowel disease: a population-based study. Gastroenterology. 2001;121(2):255–60.

    Article  CAS  PubMed  Google Scholar 

  5. Ratman D, Vanden Berghe W, Dejager L, Libert C, Tavernier J, Beck IM, De Bosscher K. How glucocorticoid receptors modulate the activity of other transcription factors: a scope beyond tethering. Mol cell endocrinol. 2013;380(1–2):41–54.

    Article  CAS  PubMed  Google Scholar 

  6. Avina-Zubieta JA, Abrahamowicz M, De Vera MA, Choi HK, Sayre EC, Rahman MM, Sylvestre MP, Wynant W, Esdaile JM, Lacaille D. Immediate and past cumulative effects of oral glucocorticoids on the risk of acute myocardial infarction in rheumatoid arthritis: a population-based study. Rheumatology. 2013;52(1):68–75.

    Article  CAS  PubMed  Google Scholar 

  7. Schacke H, Docke WD, Asadullah K. Mechanisms involved in the side effects of glucocorticoids. Pharmacol ther. 2002;96(1):23–43.

    Article  CAS  PubMed  Google Scholar 

  8. Corrigan CJ, Brown PH, Barnes NC, Szefler SJ, Tsai JJ, Frew AJ, Kay AB. Glucocorticoid resistance in chronic asthma. Glucocorticoid pharmacokinetics, glucocorticoid receptor characteristics, and inhibition of peripheral blood T cell proliferation by glucocorticoids in vitro. Am rev respir dis. 1991;144(5):1016–25.

    Article  CAS  PubMed  Google Scholar 

  9. Haczku A, Alexander A, Brown P, Assoufi B, Li B, Kay AB, Corrigan C. The effect of dexamethasone, cyclosporine, and rapamycin on T-lymphocyte proliferation in vitro: comparison of cells from patients with glucocorticoid-sensitive and glucocorticoid-resistant chronic asthma. J allergy clin immunol. 1994;93(2):510–9.

    Article  CAS  PubMed  Google Scholar 

  10. Hearing SD, Norman M, Smyth C, Foy C, Dayan CM. Wide variation in lymphocyte steroid sensitivity among healthy human volunteers. J clin endocrinol metab. 1999;84(11):4149–54.

    CAS  PubMed  Google Scholar 

  11. Creed TJ, Lee RW, Newcomb PV, di Mambro AJ, Raju M, Dayan CM. The effects of cytokines on suppression of lymphocyte proliferation by dexamethasone. J immunol. 2009;183(1):164–71.

    Article  CAS  PubMed  Google Scholar 

  12. Hearing SD, Norman M, Probert CS, Haslam N, Dayan CM. Predicting therapeutic outcome in severe ulcerative colitis by measuring in vitro steroid sensitivity of proliferating peripheral blood lymphocytes. Gut. 1999;45(3):382–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  13. Maranville JC, Micic D, Hanauer SB, Di Rienzo A, Kupfer SS. In vitro sensitivity assays and clinical response to glucocorticoids in patients with inflammatory bowel disease. J crohns colitis. 2014;8(11):1539–47.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Dhanda AD, di Mambro AJ, Hunt VL, McCune CA, Dayan CM, Dick AD, Lee RW, Collins PL. Long-term outcome in patients with severe alcoholic hepatitis can be reliably determined using an in vitro measure of steroid sensitivity. Hepatology. 2015;61(3):1099.

    Article  CAS  PubMed  Google Scholar 

  15. Kirkham BW, Corkill MM, Davison SC, Panayi GS. Response to glucocorticoid treatment in rheumatoid arthritis: in vitro cell mediated immune assay predicts in vivo responses. J rheumatol. 1991;18(6):821–5.

    CAS  PubMed  Google Scholar 

  16. Porstmann T, Ternynck T, Avrameas S. Quantitation of 5-bromo-2-deoxyuridine incorporation into DNA: an enzyme immunoassay for the assessment of the lymphoid cell proliferative response. J immunol methods. 1985;82(1):169–79.

    Article  CAS  PubMed  Google Scholar 

  17. Rothaeusler K, Baumgarth N. Assessment of cell proliferation by 5-bromodeoxyuridine (BrdU) labeling for multicolor flow cytometry. Curr protoc cytom. 2007;7(7):31.

    PubMed  Google Scholar 

  18. Marzec M, Halasa K, Kasprzycka M, Wysocka M, Liu X, Tobias JW, Baldwin D, Zhang Q, Odum N, Rook AH, et al. Differential effects of interleukin-2 and interleukin-15 versus interleukin-21 on CD4+ cutaneous T-cell lymphoma cells. Cancer res. 2008;68(4):1083–91.

    Article  CAS  PubMed  Google Scholar 

  19. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.

    Article  CAS  PubMed  Google Scholar 

  20. Bland JM. How do I compare methods of measurement which give results in different units? https://www-users.york.ac.uk/~mb55/meas/diffunit.htm. Accessed 16 July 2016.

  21. Louvet A, Naveau S, Abdelnour M, Ramond MJ, Diaz E, Fartoux L, Dharancy S, Texier F, Hollebecque A, Serfaty L, et al. The Lille model: a new tool for therapeutic strategy in patients with severe alcoholic hepatitis treated with steroids. Hepatology. 2007;45(6):1348–54.

    Article  CAS  PubMed  Google Scholar 

  22. Kushwah R, Cao H, Hu J. Characterization of pulmonary T cell response to helper-dependent adenoviral vectors following intranasal delivery. J immunol. 2008;180(6):4098–108.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This research was funded by University Hospitals Bristol NHS Foundation Trust and Above and Beyond Charity. Additional support was received from the National Institute for Health Research (NIHR) Biomedical Research Centre based at Moorfields Eye Hospital NHS Foundation Trust and University College London Institute of Ophthalmology. The views expressed are those of the authors and not necessarily those of the National Health Service, the NIHR or the Department of Health.

Availability of data and materials

The dataset analysed during the current study is available from the corresponding author on reasonable request.

Authors’ contributions

The study was conceived by ADD and RWL. Participant recruitment and experimental work was performed by ELW, MLS, AS and PLC. DGE analyzed and interpreted the data. ADD drafted the manuscript and all authors reviewed and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

Prior ethical approval for this study was granted by the National Health Service (NHS) Health Research Authority (reference: 04/Q2002/84). All study procedures were conducted under the principles of the Declaration of Helsinki and written informed consent was obtained from all participants.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Richard W. Lee.

Additional file

Additional file 1:

BLISS correlates with clinical GC sensitivity in patients with acute severe alcoholic hepatitis. Preliminary data in 10 patients with acute severe alcoholic hepatitis demonstrates significant correlation with the Lille score (based on clinical and biochemical parameters after 7 days of GC treatment). Lille scores range from 0 to 1 with higher Lille scores associated with greater clinical GC resistance. Correlation coefficient = −0.74; p = 0.02 (DOCX 14 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Williams, E.L., Stimpson, M.L., Collins, P.L. et al. Development and validation of a novel bioassay to determine glucocorticoid sensitivity. Biomark Res 4, 26 (2016). https://doi.org/10.1186/s40364-016-0079-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40364-016-0079-y

Keywords